Got two on my tank with this variation of programming



(not mine)



Variable Speed Pump 1 and 2



WP40_Lt



Set Wave1

If Time 08:00 to 10:59 Then DuskDawn

If Time 11:00 to 14:00 Then Wave1

If Time 14:01 to 20:00 Then DuskDawn

If Time 20:01 to 07:59 Then Night

If Outlet Timer1 = ON Then Lt_Flush

If Outlet Timer2 = ON Then DuskDawn

If Outlet Timer3 = ON Then Wave2

If FeedA 000 Then OFF







WP40_Rt



Set Wave1

If Time 08:00 to 11:59 Then DuskDawn

If Time 12:00 to 14:00 Then Wave1

If Time 14:01 to 20:00 Then DuskDawn

If Time 20:01 to 07:59 Then Night

If Outlet Timer1 = ON Then Rt_Flush

If Outlet Timer2 = ON Then DuskDawn

If Outlet Timer3 = ON Then Wave2

If FeedA 000 Then OFF



Pump Profiles:



Wave1 (main daylight wave pattern)



Synchronize Enabled

Divide by 10 Enabled

Initial off time (Seconds) 0

On time (Seconds) 7

Off time (Seconds) 4

Minimum intensity 0

Maximum intensity 100





Wave2 (Similar pattern to the above but Sync is disabled which creates abit more chaos)



Synchronize Disabled

Divide by 10 Enabled

Initial off time (Seconds) 0

On time (Seconds) 7

Off time (Seconds) 4

Minimum intensity 0

Maximum intensity 100





Lt_Flush



Synchronize Disabled

Divide by 10 Disabled

Initial off time (Seconds) 0

On time (Seconds) 30

Off time (Seconds) 30

Minimum intensity 0

Maximum intensity 90





Rt_Flush



Synchronize Disabled

Divide by 10 Disabled

Initial off time (Seconds) 30

On time (Seconds) 30

Off time (Seconds) 30

Minimum intensity 0

Maximum intensity 90





DuskDawn (This is a lower flow wave pattern used intermittently during the light hours as well as before and after lights go out)



Synchronize Enabled

Divide by 10 Enabled

Initial off time (Seconds) 0

On time (Seconds) 7

Off time (Seconds) 4

Minimum intensity 0

Maximum intensity 30





Night (Sets a constant 30% flow during light off hours)



Synchronize Disabled

Divide by 10 Disabled

Initial off time (Seconds) 0

On time (Seconds) 10

Off time (Seconds) 15

Minimum intensity 30

Maximum intensity 30







Virtual Outlets



3 timers. The timers are used to create short random periods of different flow during daylight hours.





Timer1 (turns on every 120 minutes for 10 minutes. If timer 2 is on at that time, it should remain off)



OSC 120:00/010:00/000:00 Then ON

If Outlet Timer2 = ON Then OFF

If Time 19:30 to 08:00 Then OFF

If FeedA 000 Then OFF





Timer2 (turns on every 45 minutes for 15 minutes except if timer 3 is on)



OSC 045:00/015:00/000:00 Then ON

If Outlet Timer3 = ON Then OFF

If Time 19:30 to 08:00 Then OFF

If FeedA 000 Then OFF





Timer3 (turn on every 15 minutes for 5 minutes except if timer 1 is on)



OSC 015:00/005:00/000:00 Then ON

If Outlet Timer1 = ON Then OFF

If Time 19:30 to 08:00 Then OFF

If FeedA 000 Then OFF




Aucun commentaire: